Sub-Zero is the personification of design and performance refrigeration. It isn’t just an appliance, your Sub-Zero is an essential element of your superb kitchen location. It makes good sense that you wouldn’t intend to trust your refrigerator to just any kind of residence appliance repair work company. You desire a group of Sub-Zero refrigerator repair professionals that can secure your financial investment while providing the premium solution you are worthy of.
It Is Fixed Home Device Dealing with is business you should rely upon with every one of your Sub-Zero repair needs. Our specialists focus on Sub-Zero solution so you can count on that we have the abilities to finish the job right.
HOW TO USAGE THE MISTAKE CODE TROUBLESHOOTING OVERVIEW
Error Codes recommend problems joined by certain components. If error codes are subscribed, they will certainly show up before temperature level readings while in Diagnostic Setting.
REMEMBER: If Blunder Codes appear with a blinking “OPTION” annunciator prior to initiating Diagnostic Setting, the system experienced too much compressor run problem that might or might not be associated with the Error Codes showed
To initiate Diagnostic Setting, press and also hold either COLDER method, after that press the POWER key, after that launch both keys. Presently, check to see if Blunder Codes exist, making certain to toggle with all mistake and temperature analyses by pushing either COLDER crucial or either WARMER secret. (See Error Code Table Below).
If Mistake Codes appear throughout Diagnostic Mode, comply with the Blunder Code Troubleshooting Guide on the sticking to website. The left column of the troubleshooting guide information the mistake codes. The information in the appropriate column clarifies what tests to carry out and/or what task to require to manage the blunder.
KEEP IN MIND: If error codes are observed in analysis mode, a non-flashing SERVICE annunciator will certainly show up on the LCD when Diagnostic Mode ends, recommending error codes are still conserved. Error Codes should be removed from the electronic control memory by hand. To eliminate the non-flashing SERVICE annunciator as well as additionally the error codes, the difficulty needs to be fixed along with the unit has to get on, afterwards:.
On a variation UC-24C: Press the Fridge Freezer WARMER and also COLDER keys for fifteen (15) seconds.
On a style UC-24B, UC-24R, or UC-24RO: Press the Refrigerator WARMER and COLDER tricks for fifteen (15) seconds.
Error Code Table
CODE | INDICATION |
05 | Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
06 | Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
07 | Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
08 | Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
20 | Defrost under-heat with no voltage feedback through Gray/White wire at defrost start |
21 | Defrost overheat |
22 | No voltage feedback through Gray/White wire at defrost start |
23 | Defrost overheat with no voltage feedback through Gray/White wire at defrost start |
24 | Defrost under-heat |
30 | N/A |
40 | Excessive Freezer Compressor Run |
50 | Excessive Refrigerator Compressor Run |
Error Code | CAUSE | SOLUTION |
Error Code 08 | Inconsistent temperature readings in the refrigerator or freezer cabinet. | The issue may be caused by loose or faulty connections between the thermistor and the control board, or it may mean the thermistor is faulty. Refer to your owner’s manual to locate the thermistor, and ensure the wires between the thermistor and control panel are securely connected. If you do not have your original manual, you may be able to find a digital copy online. If the connections are secure, the thermistor and control panel will need to be tested to ensure functionality. Testing requires the use of a multimeter. You may need the assistance of a specialist trained in Sub-Zero refrigerator repair to diagnose and replace the faulty components. |
Error Code 08
A. If “EE” for fridge location was revealed in addition to “SOLUTION” blinking, check the following:.
Thermistor electric links as well as continuity from thermistor to J5 on control panel. Reconnect/ repairing.
Resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F( 0 ° C). Replace if malfunctioning. B. If “EE” for fridge location was NOT presented, problem is reoccuring thermistor error:.
Door not shutting appropriately. Suitable door closing problem.
Examine light switch, electrical wiring & electrical web links. Taking care of electric wiring/ web links or alter switch.
Examine thermistor electric links and link at J5 on control board. Reconnect/ fixing solution.
Analyze resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F (0 ° C). Replace if faulty.
C. If “EC 05” along with “REMEDY” were blinking before starting evaluation setting, gadget also experienced severe compressor run issue that might or may not be connected with the “05” Mistake Code. See Blunder Code 50 Test/Actions.